• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Beijing, China (Mainland)
  • Brand Name: PROFLEX
  • Model Number: PR12-200FC
  • Usage: Home Solar System,ect
  • Voltage: 12v
  • Sealed Type: Sealed
  • Maintenance Type: Free
  • Size: 558*125*328mm
  • Weight: 60kg
  • Nominal Capacity: 200AH
  • Certificate: ISO9001;ISO14000;CE
  • Technical Feature: USA Technology
  • Number of Cycles: 3000 @ 50% DoD
  • Life Time: 10years
  • Warranty Time:: 3years
  • Container and Cover: PP (UL94 V-0)
  • Operating Temperature Range: Discharge: -40°C (-40 °F) to + 71 °C (160 °F)
  • Maximum Charging Current Limit: 0.6 C10
  • Terminal: Threaded copper alloy insert terminal to accept: M8 bolt
  • Terminal Hardware Initial Torque: 18 N-m (160 in.-lbs)

Packaging & Delivery

Packaging Details Standard export carton+wooden pallet
Delivery Time 3~4 weeks

Proflex 12v 200ah Maintenance free lead carbon deep cycle solar battery

Product Description

 

Sealed Lead Carbon Battery

The advantages of Lead carbon battery:
1).The cycle life is over 30,00 cycles for 50% DOD.
2).Partial State of Charge (PSoC) : Lead sulfate formation is inevitable under PSOC operation. (Lead sulfate formation is one of the major failure reasons of AGM battery.)
3).Carbon battery wide operation temperature: -23oC to 60oC.
4).Due to add the carbon material which is good for heat conduction, carbon battery is suitable working at high temperature environment.
5).Good discharge performance in low temperature: The discharge rate of carbon battery at -20oC is 66% which is higher than the traditional lead acid battery (50%).
6).High charging current ability: The max. charging current of carbon battery is 0.6C which is higher than the traditional lead acid battery (0.2C). It can shorten the charging time and especially suitable for solar system application.
7).PROFLEX carbon battery is true front terminal battery. It is easy for maintenance. No maintenance space between tier to tier, it can save the installation area.

Applied Scope :
1. Communication Systems: Switch, Microwave Stations, Mobile Base Stations, Data Centers, Radio and Broadcasting Stations
2. Motivity Field: Robots, Electric Toys, Electric Tools & Portable Vacuum Cleaners
3. Solar & Wind Power Generation Systems
4. Signal System & Emergency Lighting Systems
5. EPS & UPS Systems

 

Nominal Voltage

12V

 Nominal Capacity (20 hour rate)

192Ah

Capacity

25oC

(77°F)

36 hour rate (11.0A)

200Ah

10 hour rate (35.4A)

175Ah

1 hour rate (132A)

116Ah

Internal Resistance

Full Charged Battery 25 °C

≤2.5mΩ

Capacity affected by Temperature 

(10 hour )

40 °C

(104°F)

102%

25oC

(77°F)

100%

0oC

(32°F)

85%

-15oC

(5°F)

65%

Self-Discharge

25oC

(77°F) Capacity

after 3 month storage

90%

after 6 month storage

80%

after 12 month storage

62%

Charge (Constant Voltage) 25oC

(77°F)

Float

Initial Charging Current Less than 40A

Voltage 13.6-13.8V

Cycle

Initial Charging Current Less than 40A

Voltage 14.4-14.9V

Note The above data are average values, and can be obtained within 3 charge/discharge cycles. These are not minimum values. Cell and battery designs/specifications are subject to modification without notice. Contact Prostar for the latest information.

 

Packaging & Shipping

 

 

 

 

Our Services

 

- Samples support

Available for on-site testing, laboratory tests as well as third party testing, sample will be ready within 7 working days

- Warranty support

From the date of shipping, we provides 18 months warranty against defects in materials and workmanship for inverter’s quality control, free spare parts 2% against definite order quantities

- After sales

We use the service speed to win customer satisfaction; we commit to resolve any service issues within 48 hours

- OEM Service

Based on the ISO9001 quality assurance, the ISO14001 Environmental protection management system certificate, as well as the ISO18001 occupational health and safety management system certificate, involves the effective teamwork of departments from sales, purchasing, designing, production, Q&A and R&D, assuring a high quality product and prompt delivery.

- Design Service

Personalized packaging design, label design, warranty card as well as catalogue

 

 

Company Information

 

 

 

 

 

 

FAQ

 

1. What is the definition of "cycle use" and "standby use"?
"Cycle Use" - direct power source:
Cycle Use It can provide the power supply to power tools, and portable electronic products. It can also be used for cycling charging and discharging usage such as electronics motorbike or vacuum cleaner.
"Standby Use" - back up power:
Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.

2. What are the concerns when using PROFLEX batteries in a parallel or a serial series?
1. Do not mix brands, models and date codes?
2. No separate discharge then charging in a serial configuration.
3. Under parallel usage, pay close attention to the differences in voltage in each circuit.
4. If the difference in voltage in each circuit is too high, do not charge/discharge as parallel.
5. The environment of all circuits must be similar.

3. How can you check a battery’s performance?
Different usage applications will use different methods for evaluating a battery’s performance. Using a 20 hour rate or the 10 hour rate, you can use 0.05CA or 0.1CA to discharge the battery until the battery reaches a terminal voltage of 10.25 volts. You can then calculate the amp hours to see if the battery fits the specifications or not. For a 5 minutes rate, such as the HC1221W, you can use a 21 watts/cell discharge till the terminal voltage reaches a terminal voltage of 9.6 volts and then measure the discharge time to see if it meets the final specifications or not.

4. How can the conversion be made between "watts (W)" and "amp hours (Ah)"?
W=I x V = 4I (15 minute rate) = 2CV = 2V
(Ex. HC1217W = 17/4 = 4.25Ah)

5. When should a deep-cycle battery be used?
Deep-cycle batteries are used when 50% or more of the capacity is used per cycle. The most common use of deep-cycle batteries is in applications that require deep, repetitive drain, like powerful car audio systems, trolling motors, golf carts, electric wheelchairs, or RV house power sources. Public safety and high-performance vehicles are other applications that call for the special characteristics of deep-cycle batteries.

6. Does the deep-cycle battery have a "memory"?
No. The performance of deep-cycle batteries will be reduced over time, but deep-cycle batteries do not suffer from "memory effect" such as NiCd batteries do.

7. How are batteries rated?
Lead acid batteries are rated based on a capacity given in a defined time. There is not a set industry standard for how to rate a battery.

8. How long can a battery last?
The service design life of a battery varies considerably with how it is used, how it is maintained and charged, temperature, among other factors.

9. Do I need to add water to my battery?
No. Sealed lead acid batteries do not require the use of water.

10. What determines the life of a VRLA battery?
Sealed lead acid battery life is determined by many factors. These include temperature, depth and rate of discharge, and the number of charges and discharges (called cycles).

11. What is the difference between float and cycle applications?
A float application requires the battery to be on constant charge with an occasional discharge. Cycle applications charge and discharge the battery on a regular basis.

12. Does overcharging damage batteries?
OVERCHARGING is the most destructive element in battery service. Usually the boater is not aware that this is occurring as he believes his alternator or battery charger is "automatic." Unfortunately, these automatic circuits are sensitive to voltage surges, heat, direct lightening strikes and indirect lightening electromagnetic influences and could fail or shift their calibration. When they fail, overcharging begins to affect the batteries. During overcharging, excessive current causes the oxides on the plates of the battery to "shed" and precipitate to the bottom of the cell and also heat the battery, thus removing water from the electrolyte. Once removed, this material (which represents capacity) is no longer active in the battery. In addition, the loss of water from the electrolyte may expose portions of the plates and cause the exposed areas to oxidize and become inactive, thus reducing additional capacity. Sealed batteries are not immune from the same internal results when overcharged. In fact, sealed recombination absorption and gel batteries are particularly sensitive to overcharging. Once moisture is removed from the battery, it cannot be replaced. Portions of the battery damaged due to overcharging are irretrievable. However, if detected early, corrective adjustments to the charging device will save the undamaged portion of the battery. Initial signs of overcharging are excessive usage of water in the battery, continuously warm batteries, or higher than normal battery voltages while under the influence of the charger. If overcharging is suspected, correct immediately.

  

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer, Trading Company
Transaction Level:
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $133,000
Learn More